How-to guideCleaning & Laundry

How Do You Test A Dryer Heating Element Step by Step

Updated 9 min read

Reader-supported: when you buy through links on our site, we may earn an affiliate commission at no extra cost to you. As an Amazon Associate, we earn from qualifying purchases. Learn more.

If your dryer runs but leaves clothes cold and damp, the heating element may be the culprit—but guessing can lead to replacing a perfectly good part. A multimeter can help you check the element in a few careful steps. You’ll need to disconnect the dryer from power, find the element, and measure its electrical resistance. Here’s how to do that safely, what the readings mean, and what to check if the element passes the test.

What the dryer heating element does

An electric dryer’s heating element is a coil of resistance wire. When electricity flows through it, the wire gets hot, and a blower pushes air past it and through the drum. If the coil breaks, electricity can’t complete its path, so the dryer may tumble normally without producing heat.

Not every no-heat problem comes from the element, though. A blown thermal fuse, faulty thermostat, damaged wiring, or power-supply issue can cause similar symptoms. Testing the element is useful because it lets you rule it in or out before buying a replacement.

One important distinction: gas dryers don’t use an electric heating element. They heat air with a gas burner, though they still have electrical parts such as an igniter and sensors. The steps below are for an electric dryer.

Safety comes first

A dryer can use dangerous voltage, and its metal cabinet may have sharp edges. Never test resistance on a dryer that’s plugged in. A multimeter’s ohms setting sends its own small signal through the part, so the appliance must be disconnected from the power source first.

  • Unplug the dryer. If it’s hardwired, switch off the correct breaker and confirm the appliance is disconnected.
  • If you’re unsure whether power is off or how to access the dryer safely, stop and call a qualified appliance technician.
  • Wear work gloves if you have them, and keep screws and panels organized as you remove them.
  • Don’t bypass a thermal fuse or thermostat to make the dryer run. Those parts help prevent overheating and fire.

Electric dryers often use a 240-volt supply, which may have two breakers linked together. Turning off only one side may not make the appliance safe to work on. Unplugging it is the simplest option when the plug is accessible.

What you’ll need

  • A digital multimeter with an ohms (Ω) setting
  • A screwdriver or nut driver that fits your dryer’s fasteners
  • Your dryer’s model number and service manual, if available
  • A phone or labels to help you remember where wires connect

Before opening the dryer, find the model number. It’s often on a label inside the door opening or around the door frame. The manual or a manufacturer parts diagram can show where the heating assembly sits and what resistance range to expect for that exact model.

How to test a dryer heating element step by step

1. Confirm the dryer is unplugged

Pull the plug from the wall rather than relying only on the controls being off. If the dryer is hardwired, switch off the breaker and verify power is disconnected with an appropriate tester. Don’t proceed if you can’t confidently confirm that the appliance is de-energized.

2. Get access to the heating element

The location varies by brand and design. On many electric dryers, the element is inside a metal heater housing behind the rear panel or near the lower front of the cabinet. Some models require removing a drum or another major part to reach it.

Follow the service instructions for your model rather than prying off panels or pulling on wires. Take a photo before disconnecting anything. That quick reference can save a lot of head-scratching when it’s time to put the dryer back together.

3. Find the element terminals and disconnect a wire

The heating coil sits inside a metal housing and connects to the dryer’s wiring at terminals. Once you’ve located those terminals, carefully remove at least one wire from the element. Pull on the connector, not the wire itself.

Disconnecting a wire separates the element electrically from other components. If you leave the wiring attached, the multimeter may find another path through the circuit, giving you a reading that doesn’t belong to the element alone.

4. Set up the multimeter

Put the black lead in the meter’s COM socket and the red lead in the socket marked for volts, ohms, or both. Select resistance, shown as Ω. If your meter has manual ranges, choose a low range such as 200 ohms. If it selects the range automatically, simply choose Ω.

Touch the two probe tips together briefly. Many meters show a reading close to zero, confirming the leads and meter are working. Some beep in continuity mode. That beep is handy for checking whether a circuit is open or closed, but resistance mode gives you more useful detail for a heating element.

5. Measure across the element terminals

Place one probe on each of the element’s electrical terminals. Keep the probe tips on the metal contacts, not on the surrounding housing. Wait for the display to settle, then write down the reading.

A working element usually shows a finite resistance: a number of ohms. An open or broken coil typically shows “OL,” “open,” or an extremely high reading. The exact display depends on your meter.

Don’t assume every healthy element must show one particular number. The correct resistance depends on the dryer’s design and the element’s rated wattage. Check the manual or manufacturer’s service information for the specification.

6. Check whether the coil is grounded

Leave the wire disconnected. Put one probe on an element terminal and the other on the bare metal heater housing or another unpainted metal part of the assembly. Repeat with the other terminal.

In a basic element test, each terminal should show no electrical connection to the metal housing. The meter will usually display “OL” or no continuity. If it shows a measurable resistance or beeps, the coil may be touching the housing. That can cause an electrical fault and may trip a breaker.

Meter resultWhat it may meanWhat to do next
Finite resistance across the terminals, within the model’s specified rangeThe coil has continuity and may be electrically soundCheck the thermostat, thermal fuse, wiring, and power supply if the dryer still doesn’t heat
“OL,” open, or extremely high resistance across the terminalsThe element may have a break in the coilCompare with the service information; replace the element if the open reading is confirmed
Continuity or measurable resistance from a terminal to the housingThe element may be grounded against its metal housingDon’t run the dryer; inspect or replace the faulty assembly
Reading changes when a probe is movedA probe may not be making solid contact, or a terminal may be loose or damagedReposition the probes and inspect the terminals before deciding the part has failed

How to understand the resistance reading

A heating element’s resistance is related to its voltage and power rating. In a simple resistive circuit, the relationship is resistance = voltage squared ÷ power. For example, a hypothetical 240-volt, 5,000-watt element would calculate to about 11.5 ohms.

That example helps explain why a good dryer element may show a relatively low number rather than hundreds of ohms. But it isn’t a universal pass-or-fail value. Dryer designs, voltage ratings, and element configurations differ, so use the specification for your model whenever possible.

A continuity beep alone can be misleading, too. It usually tells you there’s some path for current, not whether the resistance is correct for that specific element. Use the ohms reading and compare it with the manufacturer’s information.

If the element passes, check the next likely causes

A normal element reading doesn’t prove the whole heating system is working. It only suggests that the coil itself has continuity and isn’t obviously grounded. If the dryer still runs cold, the fault may be elsewhere.

  • Thermal fuse: A blown fuse can interrupt the heating circuit. Test it only with power disconnected, and replace it with the correct part if it’s faulty. Also investigate overheating causes, such as blocked airflow.
  • Thermostat or temperature sensor: These parts control or monitor heat. A failed component can prevent the element from switching on or cause incorrect heating.
  • Power supply: Many electric dryers can tumble even when one side of their 240-volt supply is missing. If you’re not trained to test electrical supply safely, have an electrician or appliance technician check it.
  • Vent blockage: A clogged lint screen, crushed vent hose, or blocked outside vent can restrict airflow. Poor airflow can cause overheating and trip safety components.
  • Wiring or connections: A loose, burned, or broken wire can stop power from reaching the element even when the coil tests correctly.

If the dryer heats briefly and then stops, airflow or a temperature-control problem may be more likely than a completely broken coil. If it never heats and the element reads open, the element becomes a stronger suspect—but confirm the model-specific test before ordering parts.

Common testing mistakes to avoid

The easiest mistake is checking resistance while the dryer is still connected to power. That can damage the meter or expose you to a dangerous shock. Another common error is leaving both element wires connected, which can let other components affect the reading.

Also avoid bending or stretching the coil while inspecting it. A damaged coil can break, and a coil that sags or touches the housing can create a new problem. If you see a broken section, heavy corrosion, or signs of burning, stop and replace the damaged part with the correct model-compatible assembly.

When you’re done testing, reconnect the wires exactly as they were and reinstall every panel before restoring power. If you can’t confidently put the dryer back together, or the wiring looks burned, get help rather than running it with a panel missing.

Read more related posts:

Frequently Asked Questions

Can I test a dryer heating element without removing it?

Sometimes you can reach the terminals without removing the whole heater assembly. You still need to disconnect the dryer from power and remove at least one wire from the element to avoid misleading readings. Follow the service instructions for your model.

What should a good dryer heating element read?

It should normally show a finite resistance, but the correct value varies by model and element rating. Check the manufacturer’s service information rather than relying on a single number found online.

What does “OL” mean on my multimeter?

“OL” usually means the meter detects an open circuit or a resistance beyond its selected range. Across the element terminals, that can point to a broken coil. Confirm the meter is set correctly and the probes are making good contact before replacing the part.

Why does my dryer run but not heat?

The element could be open, but other causes include a blown thermal fuse, faulty thermostat, damaged wiring, blocked airflow, or a missing part of the electrical supply. Testing the element helps narrow the problem; it doesn’t check the entire dryer.

Conclusion

To test an electric dryer heating element, unplug the dryer, access the element, disconnect a wire, and measure resistance across its terminals. A finite reading within the model’s specification suggests continuity; an open reading may mean the coil has failed. Then test each terminal against the metal housing to look for a ground fault.

If the element passes, don’t replace it just because the dryer is cold. Check the thermal fuse, temperature controls, wiring, power supply, and vent airflow—or ask a qualified technician to help. A careful test can save you money, and taking the safety steps seriously helps protect both you and your home.

Rate this post
Spread the love

Sponsored

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top